How Did My Ground and Neutral Become Energized by a Short in the Buried Main Line?

I think the power guy's assessment was spot-onHe said it appeared that the buried cable coming in from the street had degraded or been damaged and that the "hot must have nipped the neutral."What was happening is that the incoming hot probably contacted the ground indirectly via the insulation failing in some fashion. Your neutral bonds with the ground in your main service panel, and are fed into a series of grounding rods near your panel. As such, your panel and all electrical switches and receptacles attach to this point (via grounding wire) and the powerful draw of the service neutral prevents it from flowing through you instead (which is why you don't bond ground and neutral anywhere else).What it sounds like is that the shielding on the incoming service wire degraded and was able to put that power into the ground nearby, which was then picked up by the grounding rods (this process would be amplified if the ground was wet from recent rains). This then reversed the process, where your ground and neutral now became live. This is evidenced byWhat, if anything, I need to do to ensure there are no hazardous conditions in my homeIt wouldn't hurt to have an electrician come out and inspect the panel. I wouldn't open a main panel myself, since the incoming hots from your power company cannot be turned off by you (that main breaker just cuts power to the rest of the panel). Specifically, make sure nothing in the panel was damaged, and that the ground and neutral bond look OK.

Next, take your contactless tester and try them against a ground and neutral wire. You shouldn't get any reading from them (unless electricity is flowing through your receptacle from a downstream source). A wiring tester would also help in this case.

Once the power company has permanently replaced the wire, you should be just fine

Long post, because I'm not sure what information is critical. The ultimate question is what, if anything, I need to do to ensure there are no hazardous conditions in my home.

Friday night, the lights flickered for 10 seconds and then the house lost power. (Mostly, it turns out.) No other house on the block lost power. I went out to the service panel. I could see the meter was not on.

When I touched the service panel, I got a shock and dropped the door. I got my no contact tester (not a volt meter but the light up stick) and it lit up and beeped when I touched the panel box. I turned the main breaker off with a wooden spoon. I touched the box again and it again showed voltage even with the main breaker off. I then started testing other things. It lit up on the ground wire. It lit up on the hose bib. I yelled into the house and told everyone not to move. I tested the door handle and it was ok. I got everyone and the dog out of the house and into the car for warmth and called the power company.

I went back in with the tester, testing everything before I touched it. Pretty much every thing I tested in the house that was connected to the electrical system showed a positive test. The outside of the metal oven. The frame of the tv. Metal lamps (the actual lamp, not just the cord.) A laptop that was plugged in (the laptop itself.) Each switch cover. Most peculiar, low power led lights in our range hood were on at about 20 percent their usual strength. (They are not on a batter back up.) The GFIs in my kitchen were tripped, but their lights were on, showing red (not green, as usual). The refigerator was getting some power, very weakly.

The guy from the power company got there a few hours later. He was initially confused about what was going on. He asked whether we had any solar or batteries or generators that could be "backfeeding" the electrical system. (We don't.) He unscrewed the lines feeding the house from the meter. As soon as he disconnected the last of them, everything stopped testing positive with the non-contact voltage meter. The lights in the stove went out. He tested each of the wires that were coming in from the street, which had been disconnected from the meter. It appeared to me, but I'm not sure because I was standing a respectful distance away, that he got a voltage reading on the neutral. He said it appeared that the buried cable coming in from the street had degraded or been damaged and that the "hot must have nipped the neutral." I wanted to ask more, but I also wanted to let him do his thing.

He ran a temporary above ground cable that restored power and said the company would install a new underground cable from the street this week. He cleared us to go back in the house. I tested things with my voltage meter and it was all ok. Everything was working fine, except the high speed internet. The guy from cox came yesterday. He found that the connector from the box across the street, which feeds the line to my house, was completely fried and melted. He said he had never seen that, but that it had "done its job." I think he was saying that the coaxial cable is grounded at my house and so current must have zapped it along the ground? I don't really understand. I looked at where the coax enters my house and there is a box on the outside of my house with a ground wire that comes out of the box and is clamped to a copper water line.

Anyway, seeing the melted cable freaked me out a little.

I did a bunch of reading on what could cause a house to have power if the main breaker is off. None of it makes sense. And how would my copper plumbing show positive? And why didn't any of my breakers trip?

Let's say that the insulation between the hot and neutral wore out beneath the ground, feeding my house. Could this explain it? That would put current on the neutral coming into the house. Could that serve as power to everything the house and the grounding system that flows independent of the breakers? Why wouldn't that be a short circuit that would trip a fuse or breaker in the transformer box at the street?

Anyway, the "why" is less important to me than understanding if there are likely to be unseen dangers in the house as a result of this incident and what, if anything, I can do about that. I guess the power company guys will be back to re-install cable to my house and I can ask them, but I'd like to be educated. I can't find anything like this on the internet. Many thanks.

·OTHER ANSWER:

Long post, because I'm not sure what information is critical. The ultimate question is what, if anything, I need to do to ensure there are no hazardous conditions in my home.

Friday night, the lights flickered for 10 seconds and then the house lost power. (Mostly, it turns out.) No other house on the block lost power. I went out to the service panel. I could see the meter was not on.

When I touched the service panel, I got a shock and dropped the door. I got my no contact tester (not a volt meter but the light up stick) and it lit up and beeped when I touched the panel box. I turned the main breaker off with a wooden spoon. I touched the box again and it again showed voltage even with the main breaker off. I then started testing other things. It lit up on the ground wire. It lit up on the hose bib. I yelled into the house and told everyone not to move. I tested the door handle and it was ok. I got everyone and the dog out of the house and into the car for warmth and called the power company.

I went back in with the tester, testing everything before I touched it. Pretty much every thing I tested in the house that was connected to the electrical system showed a positive test. The outside of the metal oven. The frame of the tv. Metal lamps (the actual lamp, not just the cord.) A laptop that was plugged in (the laptop itself.) Each switch cover. Most peculiar, low power led lights in our range hood were on at about 20 percent their usual strength. (They are not on a batter back up.) The GFIs in my kitchen were tripped, but their lights were on, showing red (not green, as usual). The refigerator was getting some power, very weakly.

The guy from the power company got there a few hours later. He was initially confused about what was going on. He asked whether we had any solar or batteries or generators that could be "backfeeding" the electrical system. (We don't.) He unscrewed the lines feeding the house from the meter. As soon as he disconnected the last of them, everything stopped testing positive with the non-contact voltage meter. The lights in the stove went out. He tested each of the wires that were coming in from the street, which had been disconnected from the meter. It appeared to me, but I'm not sure because I was standing a respectful distance away, that he got a voltage reading on the neutral. He said it appeared that the buried cable coming in from the street had degraded or been damaged and that the "hot must have nipped the neutral." I wanted to ask more, but I also wanted to let him do his thing.

He ran a temporary above ground cable that restored power and said the company would install a new underground cable from the street this week. He cleared us to go back in the house. I tested things with my voltage meter and it was all ok. Everything was working fine, except the high speed internet. The guy from cox came yesterday. He found that the connector from the box across the street, which feeds the line to my house, was completely fried and melted. He said he had never seen that, but that it had "done its job." I think he was saying that the coaxial cable is grounded at my house and so current must have zapped it along the ground? I don't really understand. I looked at where the coax enters my house and there is a box on the outside of my house with a ground wire that comes out of the box and is clamped to a copper water line.

Anyway, seeing the melted cable freaked me out a little.

I did a bunch of reading on what could cause a house to have power if the main breaker is off. None of it makes sense. And how would my copper plumbing show positive? And why didn't any of my breakers trip?

Let's say that the insulation between the hot and neutral wore out beneath the ground, feeding my house. Could this explain it? That would put current on the neutral coming into the house. Could that serve as power to everything the house and the grounding system that flows independent of the breakers? Why wouldn't that be a short circuit that would trip a fuse or breaker in the transformer box at the street?

Anyway, the "why" is less important to me than understanding if there are likely to be unseen dangers in the house as a result of this incident and what, if anything, I can do about that. I guess the power company guys will be back to re-install cable to my house and I can ask them, but I'd like to be educated. I can't find anything like this on the internet. Many thanks.

GET IN TOUCH WITH Us
recommended articles
News
Development Direction of Solar Street Lamp Manufacturers
Development Direction of Solar Street Lamp Manufacturers
There are many solar street lamp manufacturers. In the face of fierce competition in the industry, solar street lamp manufacturers have to face some problems if they want to develop. If they want customers to find you or patronize you again, the premise is that you are a good manufacturer in all aspects, What kind of development direction should solar street lamp manufacturers have now?If the solar street lamp price has an impact on customers, it can only be that the solar street lamp manufacturer has not really succeeded. Because the price war is never an inevitable factor for the development of manufacturers. Today, you can give customers a very low price and reduce the street lamp price by reducing the Watts actually needed by customers. It may not be guaranteed that another manufacturer will use the same method to reduce the price and attract customers. You are lowering the price, and your opponent is also lowering the price. In this way, long-term development will only hurt both sides.Therefore, the price war is not the correct development direction of solar street lamp manufacturers. The correct direction should be to focus on product production, improve product quality and cost performance, and do a good job in after-sales service at the same time. It's like a 99 yuan smartphone and a Samsung phone with hundreds or even 3000 yuan. There is a big difference in price, but we still choose Samsung phone because of its high brand, good performance and cost performance in all aspects. Therefore, the development direction of solar street lamp manufacturers should not tangle in price, but do a good job in their products and improve their brand.
Industry: LED Industry Reshuffle Through Three Forces
Industry: LED Industry Reshuffle Through Three Forces
The collapse of small and micro led enterprises last year has opened the curtain of the reshuffle of China's LED industry. Since the beginning of this year, three major factors, such as the rising threshold of government procurement, the continuous tide of IPO listing and the introduction of industry standards, will accelerate the process of reshuffle in the LED industry.On March 20 this year, the "2012 financial subsidy promotion project for semiconductor lighting products" organized by the Ministry of finance, the national development and Reform Commission and the Ministry of science and technology held a domestic public bidding in Beijing, involving led downlights and reflective self ballasting LED lights for indoor lighting, LED street lights and led tunnel lights for outdoor lighting, Nearly 300 bidding representatives from 110 enterprises across the country participated in the bidding activities.The national development and Reform Commission made it clear that in 2012, the Chinese government will spend 40 billion yuan on the procurement of LED street lamps and provide 30% financial subsidies to LED street lamp users. Since March this year, all lighting projects and new planning areas invested by the provincial government have used LED electrodeless lamps in the field of public lighting, which is estimated to bring a market of hundreds of billions of yuan.Don't think that the government will "sprinkle pepper" again. An entrepreneur who participated in the bidding on March 20 revealed that the national bidding raised the threshold. For example, products should have energy-saving certification. The province also invited tenders for LED products entering the indoor lighting of public works this year. So far, downlights of 3 enterprises, spotlights of 3 enterprises, bulb lamps of 6 enterprises and fluorescent lamps of 22 enterprises have won the bid.Facing the industry pattern of "small and scattered", the government began to realize that it is necessary to support powerful enterprises to become bigger and stronger.More and more led enterprises are listed, which will become another important force for industry integration. After development in recent years, the total number of Listed Companies in the LED industry has been close to 40, and not a few are lining up for listing. It is expected to produce some industry leaders who can compete with international giants.According to the data of provincial Lighting Appliance Association, from 2010 to now, more than 100 LED projection lamp enterprises have completed the share reform, and the Pearl River delta accounts for 51.5%; The listed led enterprises account for about 61.5%, including Hongli optoelectronics, Zhouming technology, etc; There are also some ready to be listed, such as Shenzhen Jiawei Co., Ltd., which exports solar LED outdoor lights for 1 billion yuan a year, and will be listed soon.After the listing of led enterprises, it is not only conducive to establish their own good brand image in the chaotic market, but also can use capital means to acquire and merge, expand themselves and purify the market. Zhouming technology said that if it encounters a good project, it does not rule out the possibility of acquisition.The third force of integration comes from the continuous improvement of industry standards. The national standardization management committee recently held the first working meeting of the semiconductor lighting standard leading group, involving the national development and Reform Commission, the Ministry of science and technology, the Ministry of industry and information technology, the Ministry of housing and urban rural development, the Ministry of Finance and other departments. This is the first time that the industry has uniformly planned and deployed the semiconductor lighting standardization work at the national level Light source and lamps, lighting application and energy efficiency.The Provincial Department of science and technology will also announce the progress in the formulation of semiconductor lighting standards this week. At present, 130 standard items have been listed, and led enterprises can participate in the revision of industry standards through bidding.It can be predicted that with the gradual improvement of industry standards, the LED metal halide lamp industry will bid farewell to the mixed situation. In the upcoming 12th Five Year Plan for semiconductor lighting, the state pointed out that by 2015, the scale of semiconductor lighting industry will reach 500 billion yuan, and cultivate 20 30 leading enterprises with independent brands and independent intellectual property rights, and 40 50 innovative high-tech enterprises
I Would Like to Ask What Are the Ways to Improve the Brightness of Solar Street Lamps?
I Would Like to Ask What Are the Ways to Improve the Brightness of Solar Street Lamps?
I would like to ask what are the ways to improve the brightness of solar street lamps?1. Determine the brightness of LED solar street lamp before purchaseBefore purchasing solar street lamps, if it is a large number of recycling, the best thing is to choose manufacturers with industrial plants and drive to the processing plant to have a look. If you decide where to buy, you must talk to the other party about the regulations on chromaticity. If you don't have much definition of this chromaticity, you can let the other party make a sample to have a look.If the requirements for chromaticity are very high, the size of LED light source should be larger. Some manufacturers will choose the most suitable scheme for you out of your own consideration. If it is not particularly bright according to your specific situation, you can also listen to the manufacturer's suggestions.2. Lower the LED solar street lamp equipmentIf solar street lamps are to be installed on both sides of the road, we should fully consider whether there are green plants on both sides of the road. Because the solar street lamp is converted into electromagnetic energy by digesting and absorbing solar energy, if something blocks it, the actual effect is undoubtedly impossible to be very good. When such a situation does occur, why not reduce the height of the solar street lamp and not completely cover the solar panel.3. Query LED solar street lamps on timeMany solar street lamp projects are not easy to hold meetings after the equipment is good, which is naturally not very good. Although solar energy does not need maintenance or cleaning by full-time personnel, it must be queried on time. The damaged position should be repaired immediately. If the solar panel has not been removed for a long time, it also needs to be inadvertently scrubbed.
Technicians Tell You: What Is the Construction Scheme of Solar Street Lamps
Technicians Tell You: What Is the Construction Scheme of Solar Street Lamps
Today, solar street lamps not only illuminate the road for people, but also save energy consumption for national energy consumption. They are not only environmental protection products, but also cost saving and contribute to the country.1. Selection of disassembly and assembly location: the disassembly and assembly location shall be near the installation location to facilitate transportation after assembly. In addition, the installation point shall be paved with rainproof cloth to place the wear, scratch and stain caused by the bulge or fine sand and stain on the ground.2. Installation personnel and tools: there are 3-6 professional installation personnel (personnel can be appropriately increased for heavy installation tasks), and each person is equipped with a set of installation tools, including a multimeter, a large movable port (installing anchor nuts) and a small movable port (installing other nuts), a flat screwdriver, a triangular lock tooling, a cross screwdriver and a pointed nose pliers, several rolls of insulating tape and waterproof tape, etc. In addition, there must be a crane and a lift truck.3. Count the lamps according to the delivery list: disassemble and check all parts one by one with reference to the packing list, and check whether there is any damage such as collision, wear, deformation and scratch. The installation of unqualified products is prohibited.4. The lamp pole components and easily worn accessories (components and lamp caps) must be padded with soft pads to avoid unnecessary damage such as scratches during installation.5. When the lower lamp pole assembly is placed, its upper end must be supported by an iron frame to facilitate the installation of the upper lamp pole assembly.1. Assembly of lamp pole assembly: upper lamp pole assembly, lower lamp pole assembly, lamp arm assembly and solar cell assembly fixing structure.A. Install the lamp arm: bind the exposed sheath wire end on the lower lamp pole with thin iron wire and wrap it with black tape: the other end of the thin iron wire passes through the lamp arm assembly; Slowly pull the thin iron wire at the top of the lamp arm assembly so that the thin iron wire with the movable sheath wire passes through the lamp arm assembly. At the same time, the lamp arm assembly gradually approaches the lower lamp pole until the panel on the lamp arm is aligned and close to the lamp arm boss on the lower lamp pole, and then fasten the lamp arm assembly on the lower lamp pole with appropriate bolts; When fixing the lamp arm assembly, avoid squeezing the sheath wire, resulting in damage or even cutting of the sheath wire skin; Disconnect the thin wire from the sheath.B. Installation of lamps (equipped with equal source): close the opened lamps to the upper end of the lamp arm, and the exposed sheath wire passes into the lamps from the tail of the lamps; Pull the sheath wire and insert the lamp into the lamp arm at the same time. The overlapping length of the two is 150mm; Connect the sheath wire to the wiring terminal inside the lamp, and pay attention to the correct positive and negative wiring during wiring. Rotate the lamp with the lamp arm as the neutral so that the lampshade is facing the ground, and then fix the lamp on the arm; Turn off the lights.C. Pole assembly on assembly:1) Fasten the bracket assembly and corner post on the upper lamp post assembly in turn, and the threaded connection parts shall be stressed evenly and fastened; While connecting the support and the angle steel frame, use fine iron wire to lead the sheath wire from the lamp pole to the angle steel frame through the support assembly;2) . place the component guard in the angle steel frame, and then place the component on the guard; When placing the components, the junction box shall be at a high place. When the components are placed horizontally, the junction box shall be close to the light pole assembly;3) . connect the components according to the system voltage and component voltage of the street lamp. If the system voltage of the street lamp is 24V and the component voltage is 17V or 18V, the components shall be connected in series. The series connection mode is that the positive pole (or negative pole) of the first component is connected with the negative pole (or positive pole) of the second component. If the component voltage is 34V, the components shall be connected in parallel, The parallel method is to connect the positive and negative poles of the first component and the positive and negative poles of the second component correspondingly. When connecting, press the small slotted screwdriver to the terminal of the junction box. The red wire is required to connect the positive pole and the blue wire to the negative pole. After wiring, fasten the anti nut at the outlet end of the junction box, and apply 7091 sealing silica gel at the terminal of the junction box, The amount of glue shall be subject to the complete sealing of the incoming line in the junction box, and then the junction box cover shall be fastened without reverse buckle.4) Use a multimeter to detect whether the component wiring (connected to the controller end) is short circuited, and also to detect whether the component output voltage meets the system requirements. In fine weather, the open circuit voltage shall be greater than 18V (system voltage is 12V) or 34V (system voltage is 24V). After installing and testing the components, the power line is connected to the positive pole of the controller end, and the exposed wire core shall be wrapped with insulating tape, which shall be wrapped in two layers;Note: the components shall be handled with care during installation to avoid damage to them by tools and other instruments.5) , components and component supports are fastened with M6 * 20 bolts, N6 nuts and washers 6. During installation, the bolts shall be installed from the outside to the inside, and then the washers shall be sleeved and fastened with nuts. During fastening, the bolt joints shall be firmly connected without looseness.
This Can Be Done When the Solar Street Lamp Cannot Work (I)
This Can Be Done When the Solar Street Lamp Cannot Work (I)
1 Power loss of solar street lamp: the power loss of solar battery is due to the quality problem of the battery itself. The cheapest one is 2-3 yuan 1Ah. Generally, this is not very reliable. Problems continue to occur after using it for about a year. Therefore, to solve this problem, replace the solar battery and replace it with a better manufacturer, If it is a northern city, it should also be noted that the battery must be buried below the frozen soil layer, especially in cold places. Thermal insulation cotton should be added to the battery, because the capacity of solar energy storage battery has a great relationship with the external ambient temperature.2 The LED light source of solar street lamp is not on: it may be the most direct way for the performance of solar street lamp. The solar street lamp system is abnormal, that is, it is not on. One of the reasons why the solar street lamp is not on may also be the problem of LED light source. As a general purchaser, it is difficult to distinguish high-power LED light source. If the solar street lamp is not on, You can simply check the light source by yourself. If the system is small and the system voltage of the light source is 12V or 24V, the conventional configuration is used. The best way to detect the light source is to connect the battery directly to the light source. If the light is on, it proves to be normal.For more questions, please click the right figure to consult online customer service.
no data

Contact Us

Copyright2021@KemecoLighting

Service Support

kemeco@kmc-ltd.com

 Copyright © 2021 Kemeco |Sitemap